KEBOS POWER ,to continue a better life.
High frequency online UPS with true double-conversion design, GR11 One series provides powerful and overall protection to your sensitive devices. It can accept wider input voltage for harsh environment. Its perfect protection for your precious servers and workstations.
True double-conversion
Output power factor 1
Output voltage regulation < 1%
Higher output crest ratio 3:1
50/60Hz Frequency Converter Mode
ECO mode for energy saving
Emergency power off function (EPO)
Provides over voltage cutt-off protection and surge immunity by MOV for full time equipment protection
High power factor charger upto 1000W capacity with very low ripple current when charging battery
Low input THDi to reduce power system pollution
Adjustable charging current via LCD panel
Smart battery charger design to optimize battery performance
Generator compatible
MODEL | GR11 One -1K | GR11 One -1.5K | GR11 One- 2K | GR11 One -3K | ||||
---|---|---|---|---|---|---|---|---|
PHASE | Single phase with ground | |||||||
Capacity | 1000 VA / 1000 W | 1500 VA / 1500W | 2000 VA / 2000 W | 3000 VA / 3000 W | ||||
INPUT | ||||||||
Nominal Voltage | 100/110/115/120 /127 VAC or 200/208/220/230/240 VAC | |||||||
Voltage Range | 55 - 150 VAC ± 3 % or 110 - 300 VAC ± 3 % at 50% load 80 - 150 VAC ± 3 % or 160 - 300 VAC ± 3 % at 100% load | |||||||
Frequency Range | 40Hz ~ 70Hz | |||||||
Power Factor | ≧ 0.99 @ nominal voltage (100% load) | |||||||
THDi | ≦5% | |||||||
OUTPUT | ||||||||
Output Voltage | 100*/110*/115*/120 /127 VAC or 200*/208*/220/230/240 VAC | |||||||
AC Voltage Regulation (Batt. Mode) | ± 1% | |||||||
Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57~63Hz | |||||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | |||||||
Current Crest Ratio | 3:1 | |||||||
Harmonic Distortion | ≦ 2 % THD (Linear Load) ; ≦ 4 % THD (Non-linear Load) | |||||||
Transfer Time | AC to DC | Zero | ||||||
Inverter to Bypass | 4 ms (Typical) | |||||||
ECO to Battery mode | 8 ms (Typical), 10 ms(max) | |||||||
Wave Form (Batt. Mode) | Pure Sine Wave | |||||||
EFFICIENCY | ||||||||
AC Mode | ≧89% @ full charged battery | ≧91% @ full charged battery | ||||||
ECO Mode | ≧96% @ full charged battery | |||||||
Battery Mode | ≧88% | ≧90% | ||||||
BATTERY | ||||||||
Battery Type | 12 V / 9 AH | 12 V / 7 AH | 12 V / 9 AH | 12 V / 9 AH | 12 V / 7 AH | 12 V / 9 AH | ||
Numbers | 2 | 3 | 3 | 4 | 6 | 6 | ||
Typical Recharge Time | 3 hours recover to 95% capacity for internal battery@ 2A charging current | |||||||
Charging Current | 100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable 200/208/220/230/240 VAC models: default 2A, max. 12A adjustable | Default: 2A, Max: 8A adjustable | ||||||
Charging Voltage | 27.4VDC ± 1% | 41.1VDC ± 1% | 41.1VDC ± 1% | 54.8VDC ± 1% | 82.1VDC ± 1% | 82.1VDC ± 1% | ||
PHYSICAL | ||||||||
Dimension, D X W X H (mm) | 410 x 438 x 88 | 510 x 438 x 88 | 610 x 438 x 88 | |||||
Net Weight (without battery) (kgs) | 6.6 | 7.8 | 8.1 | 9.4 | 10.6 | 12.4 | ||
Net Weight (w/built-int battery) (kgs) | 11.6 | 14.1 | 15.5 | 19.5 | 23.3 | 27.5 | ||
ENVIRONMENT | ||||||||
Humidity | 20-95 % RH @ 0- 40°C (non-condensing) | |||||||
Noise Level | Less than 50dBA @ 1 Meter | Less than 55dBA @ 1 Meter | ||||||
Altitude | 10% de-rating for over 1000m (The altitude should not exceed 3000m) | |||||||
MANAGEMENT | ||||||||
Smart RS-232 or USB | Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | |||||||
Optional SNMP | Power management from SNMP manager and web browser | |||||||
STANDARD | ||||||||
EMC/Safety | EMC EN62040-2 C2 for CE models | |||||||
*Derate capacity to 80% when the output voltage is adjusted to 100VAC/200VAC/208VAC. | ||||||||