KEBOS POWER ,to continue a better life.
GH11 Pro is double-conversion high frequency online UPS with a output power factor 1.0 Ranging from 6KVA to 10KVA, It’s design in small footprints with DSP technology and active input power factor correction design to ensure better output voltage conditions, power quality and power performance at all times. Its dual mains inputs will secure the power reliability in power fluctuation area.
True double-conversion
DSP technology guarantees high performance
Output power factor 1
Wide input voltage range (110-300 VAC)
High efficiency up to 94%
Active input power factor correction 0.99
50Hz/60Hz frequency converter mode
Emergency power off function (EPO)
ECO mode for energy saving
Generator compatible
SNMP/USB/RS-232 communications
Adjustable battery numbers
Optional Maintenance bypass available
Optional N+X parallel redundancy
Optional OVCD protection
MODEL | GH11 Pro- 6K(L) | GH11 Pro-10K (L) | |||
---|---|---|---|---|---|
PHASE | 1 phase in / 1 phase out | ||||
CAPACITY | 6000 VA / 6000 W | 10000 VA / 10000 W | |||
INPUT | |||||
Nominal Voltage | 208/220/230/240 VAC | ||||
Voltage Range | 110~300VAC ± 3 % at 50% load 176~300VAC ± 3 % at 100% load | ||||
Frequency Range | 46~54 Hz or 56~64 Hz | ||||
Power Factor | ≧ 0.99 @ full load | ||||
THDi | <4% @100% Load, <6% @50% Load | ||||
OUTPUT | |||||
Output Voltage | 208*/220/230/240 VAC | ||||
AC Voltage Regulation (Batt. Mode) | ± 1% | ||||
Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz | ||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||
Current Crest Ratio | 3:1 (max.) | ||||
Harmonic Distortion | ≦1 % THD (Linear Load), ≦ 4 % THD (Non-linear Load) | ||||
Transfer Time | AC Mode to Batt. Mode | Zero | |||
Inverter to Bypass | zero | ||||
Wave Form (Batt. Mode) | Pure Sine Wave | ||||
Overload | AC Mode | 100%~110%: 10min ; 110%~130%: 1min ; >130% : 1sec | |||
Battery Mode | 100%~110%: 30sec ; 110%~130%: 10sec ; >130% : 1sec | ||||
EFFICIENCY | |||||
AC Mode | 94% | ||||
Battery Mode | 91% | ||||
BATTERY | |||||
Standard Model | Battery Type | 12 V / 7 AH | 12 V / 9 AH | ||
Numbers | 16 | ||||
Typical Recharge Time | 9 hours recover to 90% capacity | ||||
Charging Current (max.) | 1.0 A | ||||
Charging Voltage | 218.4 VDC ± 1% | ||||
Long-run Model | Battery Type | Depending on applications | |||
Numbers | 16-20** | ||||
Charging Current (max.) | 4.0 A | ||||
Charging Voltage | (13.65VDC x battery number) ± 1% | ||||
PHYSICAL | |||||
Standard Model | Dimension, D X W X H (mm) | 369 x 190 x 688 | 442 x 190 x 688 | ||
Net Weight (kgs) | 54 | 66 | |||
Long-run Model | Dimension, D X W X H (mm) | 369 x 190 x 318 | 442 x 190 x 318 | ||
Net Weight (kgs) | 13 | 16 | |||
ENVIRONMENT | |||||
Operation Humidity | 20-90 % RH @ 0- 40°C (non-condensing) | ||||
Noise Level | Less than 55dBA @ 1 Meter | Less than 58dB @ 1 Meter | |||
MANAGEMENT | |||||
Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and MAC | ||||
Optional SNMP | Power management from SNMP manager and web browser | ||||
* Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC or parallel system is operated. | |||||
**When using 16 pieces of batteries, the output power factor will be derated to 0.8. If using 18 or 19 pieces of batteries, the output power factor will be derated to 0.9 | |||||
***If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m. | |||||
* Product specifications are subject to change without further notice |