KEBOS POWER ,to continue a better life.



KHD & KRD11 6-10KVA series is a single-phase uninterruptible power supply with double-conversion technology and DSP control. It delivers a rated power of 6-10kva and can be used in both tower and rack configurations.
KHD & KRD11 6-10KVA series ultra-wide input voltage range rack mount Online UPS special for South America market
True double-conversion
DSP technology guarantees high performance
Output power factor 0.9
Wide input voltage range (60-150 VAC)
Active input power factor correction 0.99
50Hz/60Hz frequency converter mode
Eco mode operation for energy saving (ECO)
Emergency power off function (EPO)
Generator compatible
Charger capacity expansion to 8A for long-run models
SNMP/USB/RS-232 communications
3-stage extendable charging design for optimized battery performance
Maintenance bypass available
Adjustable battery numbers
| MODEL | KHD11- 6K(L) | KRD11- 6K(L) | KHD11-10K(L) | KRD11-10K(L) | |
|---|---|---|---|---|---|
| PHASE | 2 phase in / 2 phase out | ||||
| CAPACITY | 6000 VA / 5400 W | 10000 VA / 9000 W | |||
| INPUT | |||||
| Nominal Voltage | 100/110/115/120/127 VAC (L-N) | ||||
| Voltage Range | 60-150 VAC (Phase-N) @ 50% load 80-140 VAC (Phase-N) @ 100% load | ||||
| Frequency Range | 46~54 Hz or 56~64 Hz | ||||
| Phase Angle | 0°/120°/180°/240° | ||||
| Power Factor | ≧ 0.99 @ 100% load | ||||
| OUTPUT | |||||
| Output Voltage | 100/110/115/120/127 VAC (L-N) | ||||
| Phase Angle | 0°/120°/180°/240° | ||||
| AC Voltage Regulation (Batt. Mode) | ± 1% | ||||
| Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz | ||||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||
| Current Crest Ratio | 3:1 (max.) | ||||
| Harmonic Distortion | ≦ 2 % THD (Linear Load), ≦ 5 % THD (Non-linear Load) | ||||
| Transfer Time | AC Mode to Battery Mode | Zero | |||
| Inverter to Bypass | Zero | ||||
| Inverter to ECO | < 10ms | ||||
| Wave Form (Batt. Mode) | Pure Sine Wave | ||||
| EFFICIENCY | |||||
| AC Mode | 90.5% | 91.0% | |||
| ECO Mode | 96.0% | ||||
| Battery Mode | 87.0% | 88.0% | |||
| BATTERY | |||||
| Standard Model | Battery Type | 12 V / 7 AH | 12 V / 9 AH | ||
| Numbers | 10 pcs x 2 strings | 10 pcs x 2 strings | |||
| Typical Recharge Time | 5 hours recover to 90% capacity | 7 hours recover to 90% capacity | |||
| Charging Current (max.) | 2.0 A | 2.0 A | |||
| Float Charging Voltage | 136.5 VDC | ||||
| Long-run Model | Battery Type | Depending on applications | |||
| Numbers | |||||
| Charging Current (max.) | 8.0 A | ||||
| Float Charging Voltage | 136.5 VDC | ||||
| INDICATORS | |||||
| LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||
| ALARM | |||||
| Battery Mode | Sounding every 4 seconds | ||||
| Low Battery | Sounding every second | ||||
| Overload | Sounding twice every second | ||||
| Fault | Continuously sounding | ||||
| PHYSICAL | |||||
| Standard Model | Dimension, D X W X H (mm) | 592 x 250 x 576 | UPS unit:668 x 438 x 133(3U) Battery pack: 580 x 438 x 133(3U) | 592 × 250 × 826 | UPS unit:668 x 438 x 266(6U) Battery pack: 580 x 438 x 133(3U) |
| Net Weight (kgs) | 83 | UPS unit: 22 Battery pack: 63 | 100 | UPS unit: 45 Battery pack: 63 | |
| Long-run Model | Dimension, D X W X H (mm) | 592 x 250 x 576 | 668 x 438 x 133(3U) | 592 x 250 x 576 | 668 x 438 x 266(6U) |
| Net Weight (kgs) | 28 | 22 | 38 | 45 | |
| ENVIRONMENT | |||||
| Operation Humidity | 0-95 % RH @ 0- 40°C (non-condensing) | ||||
| Noise Level | Less than 60dBA @ 1 Meter | ||||
| MANAGEMENT | |||||
| Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC | ||||
| Optional SNMP | Power management from SNMP manager and web browser | ||||
| **If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m. | |||||
| * L means long-run model | |||||
| * Product specifications are subject to change without further notice | |||||