KEBOS POWER ,to continue a better life.
APLUS series Modular Online UPS 120-600K is a three-phase input and output Low-voltage, scalable and modular UPS for high density computing environments, including virtualized or machine learning IT applications.
The APLUS UPS delivers 50KW/60KW of efficient, reliable power in 3U of rack space. You can expand its capacity by combining 50/60 kW modules in a scalable, building block fashion to deliver 600 kW (N+1) from a single 42U rack enclosure. This powerful configuration delivers higher power density than competitive, modular solutions while dissipating only one-third of the heat.
You can design a APLUS UPS from scratch, you can also quickly deploy the KEBOS APLUS Preassembled System, which is a turnkey solution featuring easy customization, shipping and installation.
60KW for single power module in 3U
Single 42U cabinet up to 600KW
N+1 or N+X parallel redundancy for power guarantee
Modular design decreases MTTR
High scalability
Built-in maintenance bypass switch for easy maintenance without interruptible
High efficiency double conversion online UPS
Flexible battery configuration and adjustable charging current
High overload capability
Power walk-in function
MODEL | Aplus 30U-120 | Aplus 30U-180 | Aplus 42U-240 | Aplus 42U-300 | Aplus42U-420 | Aplus 42U-480 | Aplus 42U-600 |
---|---|---|---|---|---|---|---|
PHASE | 3-phase in/3-phase out | ||||||
CABINET CAPACITY* | 120KW | 180KW | 240KW | 300KW | 420KW | 480KW | 600KW |
BATTERY TYPE | External Battery | ||||||
One Power Module Capacity | 60KVA/60KW | ||||||
Max. Power Module No. | 2 | 3 | 4 | 5 | 7 | 8 | 10 |
INPUT | |||||||
Nominal Voltage | 3 x 380/400/415 VAC (3Ph+N) | ||||||
Voltage Range | -30% ~ +20% | ||||||
Nominal Frequency | 50/60Hz (Auto sensing) | ||||||
Frequency Range | 40Hz ~70Hz | ||||||
Power Factor | > 0.99 at 100% load, >0.98 at 50% load | ||||||
Harmonic Distortion (THDi) | < 3% @ 100% load | ||||||
OUTPUT | |||||||
Nominal Voltage | 3 x 380/400/415 VAC (3Ph+N) | ||||||
Voltage Regulation (Steady state) | ≦± 1% Typical (balanced load) ≦± 2% Typical (unbalanced load) | ||||||
Nominal Frequency | 50/60Hz | ||||||
Frequency Range (Synchronized range) | 46Hz ~ 54Hz or 56Hz ~ 64Hz | ||||||
Overload Capability | 1 hour for ≦ 110%, 10 mins for 111% ~ 125%, 1 min for 126%~150% and 200ms for >150% | ||||||
Harmonic Distortion | ≦1% THD (Linear Load) ≦3% THD (Non-linear Load) | ||||||
Efficiency | 96% | ||||||
BATTERY / CHARGER | |||||||
Nominal Voltage | +/- 168V ~ +/- 240V (Selectable) | ||||||
Maximum Voltage | +/- 240V (12V x 40 Pcs) | ||||||
Minimum Voltage | +/- 168V (12V x 28 Pcs) | ||||||
Floating Charge Voltage | 2.35V/Cell (2.3V~2.4V selectable) | ||||||
Boost Charging Voltage | 2.4V/Cell | ||||||
Temperature Compensation | Yes | ||||||
Maximum Charging Current (Per Power Module) | 20A (Adjustable) | ||||||
PHYSICAL | |||||||
Cabinet Dimension (D x W x H) mm | 1100 x 600 x 1475 | 1100 x 600 x 1475 | 1100 x 600 x 2010 | 1100 x 600 x 2010 | 1100 x 1200 x 2010 | 1100 x 1200 x 2010 | 1100 x 1200 x 2010 |
Net Weight (kgs) | 270 | 300 | 466 | 510 | 888 | 932 | 1020 |
ENVIRONMENT | |||||||
Operation Temperature | 0 ~ 40℃ | ||||||
Relative Humidity | 0 ~ 95% non-condensing | ||||||
Altitude *** | <1000m for Nominal power | ||||||
IP Class | IP 20 | ||||||
MANAGEMENT | |||||||
RS-232/USB | Supports Windows family, Linux and MAC | ||||||
Optional SNMP | Power management from SNMP manager and web browser | ||||||
STANDARDS | |||||||
Safety | IEC/EN 60950-1; IEC/EN 62040-1 | ||||||
EMC | IEC/EN 62040-2 Category C3 | ||||||
*When temperature is above 30℃, the output power factor will be de-rated, 0.9 at 31℃~35℃ and 0.8 at 36℃~40℃. | |||||||
** One battery module contains 10 pcs of 12V/7Ah or 12/9Ah sealed lead acid batteries in one tray. One complete battery set contains 4 battery modules. | |||||||
***If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m. |