KEBOS POWER ,to continue a better life.
GR11 LiFePO4 1K -3KVA UPS are trusted by millions of IT professionals throughout the world to protect equipment and critical data from costly interruptions by supplying reliable, network-grade power reliably and efficiently.
GR11 LiFePO4 1K -3KVA UPS with Lithium-ion batteries provides up to 3x the life of VRLA batteries
Intelligent and efficient network power protection from entry level to scalable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other .
True double-conversion
Generator compatible
Output power factor 0.9
Fast battery recharge time
Charging current is selectable through LCD
Input power factor correction
Easy battery replacement design
Long battery lifecycle > 2000
Built-in protection circuit in battery pack with UL 1973 (MH63914) certified
UN38.3 for battery transportation
MODEL | GR11 LiFePO4-1K | GR11 LiFePO4-1.5K | GR11 LiFePO4 - 2K | GR11 LiFePO4 - 3K | ||
---|---|---|---|---|---|---|
PHASE | Single phase with ground | |||||
CAPACITY | 1000 VA / 900 W | 1500 VA / 1350 W | 2000 VA / 1800 W | 3000 VA / 2700 W | ||
INPUT | ||||||
Nominal Voltage | 100/110/115/120/125/127 VAC or 200/208/220/230/240 VAC | |||||
Voltage Range | Low Line Transfer | 80 VAC / 70 VAC / 60 VAC / 55 VAC ± 3% or 160 VAC / 140 VAC / 120 VAC / 110 VAC ± 3 % based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0 | ||||
Low Line Comeback | 87 VAC / 77 VAC / 67 VAC / 62 VAC ± 3% or 175 VAC / 155 VAC / 135 VAC / 125 VAC ± 3 % based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0 | |||||
High Line Transfer | 150 VAC ± 3% or 300 VAC ± 3% | |||||
High Line Comeback | 145 VAC ± 3% or 290 VAC ± 3% | |||||
Frequency Range | 40Hz ~ 70Hz | |||||
Power Factor | ≧ 0.99 @ nominal voltage (100% load) | |||||
THDi | ≦5% @160-265 VAC or 80~140 VAC input and full linear load condition ≦10% @160-265 VAC or 80~140 VAC input and 50% linear load condition | |||||
OUTPUT | ||||||
Output Voltage | 100*/110/115/120/125/127 VAC or 200*/208*/220/230/240 VAC | |||||
AC Voltage Regulation (Batt. Mode) | ± 1% | |||||
Frequency Range (Synchronized Range) | 57~63Hz or 47 ~ 53 Hz | |||||
Frequency Range (Batt. Mode) | 60 Hz ± 0.1 Hz or 50Hz ± 0.1 Hz | |||||
Current Crest Ratio | 3:1 | |||||
Harmonic Distortion | ≦ 2 % THD (Linear Load) ; ≦ 4 % THD (Non-linear Load) | |||||
Transfer Time | AC to battery mode | Zero | ||||
Inverter to Bypass | <4 ms (Typical) | |||||
ECO to Battery mode | 8 ms (Typical) | |||||
Wave Form (Batt. Mode) | Pure Sine Wave | |||||
Overload Capacity | AC Mode | 100% < Load < 110% Overload warning only 110% < Load < 130% 5min (+/- 4sec) 130% < Load < 140% 30sec (+/- 1sec) 140% < Load 1.5sec (+/- 0.5sec). | ||||
Inverter(Battery) Mode | 100% < Load < 110% Overload warning only 110% < Load < 130% 1min (+/- 4sec) 130% < Load < 140% 2sec (+/- 1sec) 140% < Load 1.5sec (+/- 0.5sec). | |||||
EFFICIENCY | ||||||
AC Mode @Full load | 90%@ Battery fully charged | 91%@ Battery fully charged | 90%@ Battery fully charged | |||
ECO Mode @Full load | ≧96% @ full charged battery | |||||
Battery Mode @Full load | 87% | 89% | 89% | 90% | ||
BATTERY | ||||||
Battery Type** | LiFe 247500 | LiFe 485000 | LiFe 485000 | LiFe 722500 | LiFe 722500 | |
Battery Lifecycle | > 2000 | |||||
Single Cell Type | LFP26650P-260 | |||||
Battery Numbers** | 1 | 1 | 2 | 2 | 3 | |
Battery Cell Configuration | 8S3P | 15S2P | (15S2P) x 2 | (24S1P) x 2 | (24S1P) x 3 | |
Battery Voltage | 25.6V | 48V | 48V | 76.8V | 76.8V | |
Battery VAH(Factory Setting) | 7.5Ah | 5Ah | 10Ah | 5Ah | 7.5Ah | |
Autonomy Time @ Full Load | 9.5 minutes | 8 minutes | 12 minutes | 9.5 minutes | 9.5 minutes | |
Charging Voltage | 28VDC ± 1% | 52.5VDC ± 1% | 52.5VDC ± 1% | 84VDC ± 1% | 84VDC ± 1% | |
Charging Mode | 2 stage charging management(CC-CV) | |||||
Charging Current | 1A/2A/4A(Default)/6A/8A (Adjustable) | |||||
Typical Recharge Time | 2 hours recover to 90% capacity | |||||
PHYSICAL | ||||||
Dimension, D x W x H (mm) | 410 x 438 x 88 | 410 x 438 x 88 | 510 x 438 x 88 | 510 x 438 x 88 | 630 x 438 x 88 | |
Net Weight (kgs) | 10.8 | 11.6 | 15.2 | 14.4 | 20.5 | |
ENVIRONMENT | ||||||
Operating Humidity | 20-95 % RH @ 0- 40°C (non-condensing) | |||||
Noise Level | Less than 50dBA | |||||
MANAGEMENT | ||||||
Smart RS-232,USB | Supports Windows family, Linux, Unix and MAC | |||||
SNMP | Power management from SNMP manager and web browser | |||||
STANDARD | ||||||
EMC/Safety | CE (EMC: EN62040-2 C2) for HV models, FCC (Class A) for LV models, Battery Pack comply to UL1973 | |||||
*Derate capacity to 90% when the output voltage is adjusted to 100VAC/200VAC/208VAC. | ||||||
For 100/110/115/120/125/127VAC system, the output power ratings are different based on different input voltage. Please check output power rating table for the details. 127VAC is not applicable to USA region. | ||||||
Product specifications are subject to change without further notice |