AP Modular 30-42U 80-300K

AP Modular Online UPS 30U-42U 90 -300K offering high efficiency and overload capability, AP series is a truly modular UPS system which can easily scales in 30KW increments up to 210KW. Modular Design is applied in Power modules, STS module and battery module. It will simplify maintenance and replacement with low MTTR.

  • Output power factor 1

  • N+1 or N+R Parallel Redundancy for power guarantee

  • Modular design decreases MTTR

  • High scalability

  • High reliable operation with redendant power supply in STS

  • Built-in maintenance bypass switch for easy maintenance without interruptible

  • High efficiency double conversion online UPS

  • Adjustable battery numbers

  • User-adjustable charging current

  • Graphic 5.7'' LCD design for easy configuration

  • SNMP+USB+RS-232 multiple communications

Drag the table to right or left to view more.
MODELAP 30U-90HVAP 42U-120HVAP 30U-120HV
AP 30U-80-20KHV
AP 30U-180HV
AP 30U-120-20KHV
AP 42U-200-20KHVAP 42U-210HVAP 42U-300HV
PHASE3-phase in/3-phase out
CABINET CAPACITY*90KW120KW120KW or 80KW180KW or 120KW200KW210KW300KW
BATTERY TYPEBuilt-in BatteryExternal Battery
One Power Module Capacity30KVA/30KW30KVA/30KW or 20KVA/20W20KW30KVA/30KW30KVA/30KW
Max. Power Module No.344610810
Max. Battery Set No.**35-----
INPUT
Nominal Voltage3 x 380VAC/400VAC/415VAC (3Ph+N)
Voltage Range305 ~ 478 VAC at 70% - 100% load; 208 ~ 478VAC for <70% load
Nominal Frequency50/60Hz (Auto sensing)
Frequency Range40Hz ~70Hz
Power Factor> 0.99 at 100% load, >0.98 at 50% load
Harmonic Distortion (THDi)< 3% @ 100% load
OUTPUT
Nominal Voltage3 x 380VAC/400VAC/415VAC (3Ph+N)
Voltage Regulation (Steady state)≦± 1% Typical (balanced load)
≦± 2% Typical (unbalanced load)
Nominal Frequency50/60Hz
Frequency Range (Synchronized range)46Hz ~ 54Hz or 56Hz ~ 64Hz
Overload Capability1 hour for 110%, 10 mins for 125%, 1 min for 150% and 200ms for >150%
Harmonic Distortion≦ 2% THD (Linear Load)
≦ 4% THD (Non-linear Load)
BATTERY / CHARGER
Nominal Voltage+/-  216V (12V x 36 Pcs)
Maximum Voltage+/- 240V (12V x 40 Pcs)
Minimum Voltage+/- 192V (12V x 32 Pcs)
Floating Charge Voltage2.25V/Cell
Boost Charging Voltage2.35V/Cell
Temperature CompensationYes
Maximum Charging Current (Per Power Module)8A8A for 30KW power module
6A for 20KW power module
6A8A8A
PHYSICAL
Cabinet Dimension
(D x W x H) mm
1100 x 600 x 14751100 x 600 x 20101100 x 600 x 14751100 x 600 x 14751100 x 600 x 2010
Net Weight (kgs)675932335 or 333437.5 or 434.5611549620
ENVIRONMENT
Operation Temperature0 ~ 40℃
Relative Humidity0 ~ 95% non-condensing
Altitude ***<1000m for Nominal power
IP ClassIP 20
MANAGEMENT
RS-232/USBSupports Windows 2000/2003/XP/Vista/2008/7, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser
STANDARDS
SafetyIEC/EN 60950-1; IEC/EN 62040-1
EMCIEC/EN 62040-2 Category C3
*When temperature is above 30℃, the output power factor will be de-rated, 0.9 at 31℃~35℃ and 0.8 at 36℃~40℃.
** One battery module contains 10 pcs of 12V/7Ah or 12/9Ah sealed lead acid batteries in one tray. One complete battery set contains 4 battery modules.
***If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.