KEBOS POWER ,to continue a better life.
AP Modular Online UPS 30U-42U 90 -300K offering high efficiency and overload capability, AP series is a truly modular UPS system which can easily scales in 30KW increments up to 210KW. Modular Design is applied in Power modules, STS module and battery module. It will simplify maintenance and replacement with low MTTR.
Output power factor 1
N+1 or N+R Parallel Redundancy for power guarantee
Modular design decreases MTTR
High scalability
High reliable operation with redendant power supply in STS
Built-in maintenance bypass switch for easy maintenance without interruptible
High efficiency double conversion online UPS
Adjustable battery numbers
User-adjustable charging current
Graphic 5.7'' LCD design for easy configuration
SNMP+USB+RS-232 multiple communications
MODEL | AP 30U-90HV | AP 42U-120HV | AP 30U-120HV AP 30U-80-20KHV | AP 30U-180HV AP 30U-120-20KHV | AP 42U-200-20KHV | AP 42U-210HV | AP 42U-300HV |
---|---|---|---|---|---|---|---|
PHASE | 3-phase in/3-phase out | ||||||
CABINET CAPACITY* | 90KW | 120KW | 120KW or 80KW | 180KW or 120KW | 200KW | 210KW | 300KW |
BATTERY TYPE | Built-in Battery | External Battery | |||||
One Power Module Capacity | 30KVA/30KW | 30KVA/30KW or 20KVA/20W | 20KW | 30KVA/30KW | 30KVA/30KW | ||
Max. Power Module No. | 3 | 4 | 4 | 6 | 10 | 8 | 10 |
Max. Battery Set No.** | 3 | 5 | - | - | - | - | - |
INPUT | |||||||
Nominal Voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | ||||||
Voltage Range | 305 ~ 478 VAC at 70% - 100% load; 208 ~ 478VAC for <70% load | ||||||
Nominal Frequency | 50/60Hz (Auto sensing) | ||||||
Frequency Range | 40Hz ~70Hz | ||||||
Power Factor | > 0.99 at 100% load, >0.98 at 50% load | ||||||
Harmonic Distortion (THDi) | < 3% @ 100% load | ||||||
OUTPUT | |||||||
Nominal Voltage | 3 x 380VAC/400VAC/415VAC (3Ph+N) | ||||||
Voltage Regulation (Steady state) | ≦± 1% Typical (balanced load) ≦± 2% Typical (unbalanced load) | ||||||
Nominal Frequency | 50/60Hz | ||||||
Frequency Range (Synchronized range) | 46Hz ~ 54Hz or 56Hz ~ 64Hz | ||||||
Overload Capability | 1 hour for 110%, 10 mins for 125%, 1 min for 150% and 200ms for >150% | ||||||
Harmonic Distortion | ≦ 2% THD (Linear Load) ≦ 4% THD (Non-linear Load) | ||||||
BATTERY / CHARGER | |||||||
Nominal Voltage | +/- 216V (12V x 36 Pcs) | ||||||
Maximum Voltage | +/- 240V (12V x 40 Pcs) | ||||||
Minimum Voltage | +/- 192V (12V x 32 Pcs) | ||||||
Floating Charge Voltage | 2.25V/Cell | ||||||
Boost Charging Voltage | 2.35V/Cell | ||||||
Temperature Compensation | Yes | ||||||
Maximum Charging Current (Per Power Module) | 8A | 8A for 30KW power module 6A for 20KW power module | 6A | 8A | 8A | ||
PHYSICAL | |||||||
Cabinet Dimension (D x W x H) mm | 1100 x 600 x 1475 | 1100 x 600 x 2010 | 1100 x 600 x 1475 | 1100 x 600 x 1475 | 1100 x 600 x 2010 | ||
Net Weight (kgs) | 675 | 932 | 335 or 333 | 437.5 or 434.5 | 611 | 549 | 620 |
ENVIRONMENT | |||||||
Operation Temperature | 0 ~ 40℃ | ||||||
Relative Humidity | 0 ~ 95% non-condensing | ||||||
Altitude *** | <1000m for Nominal power | ||||||
IP Class | IP 20 | ||||||
MANAGEMENT | |||||||
RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008/7, Linux and MAC | ||||||
Optional SNMP | Power management from SNMP manager and web browser | ||||||
STANDARDS | |||||||
Safety | IEC/EN 60950-1; IEC/EN 62040-1 | ||||||
EMC | IEC/EN 62040-2 Category C3 | ||||||
*When temperature is above 30℃, the output power factor will be de-rated, 0.9 at 31℃~35℃ and 0.8 at 36℃~40℃. | |||||||
** One battery module contains 10 pcs of 12V/7Ah or 12/9Ah sealed lead acid batteries in one tray. One complete battery set contains 4 battery modules. | |||||||
***If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m. |