KEBOS POWER ,to continue a better life.
KIL series home inverter use line interactive UPS design concept, all digital control of the real pure sine wave output; Low frequency design with superior impact resistance capacity,to meet the requirement of different equipment; Adjustable AC charging voltage and charging current, free choice of working mode, to meet different types of the user1 s requirements.
Regular Mode : The system always keeps output. When there is electricity power, the AC charging function is always maintained. If no AC, battery will discharge in inverter mode, and it will not shut down until it reaches low battery voltage. Once the AC recovers, it will auto restart.
AC charging current max 60A, to meet customer requirements for fast charging
Adjustable AC charging voltage, to adapt to different types of batteries
Adjustable AC charging current, to meet the different capacity of the battery
Model | KIL0.3K | KIL0.6K | KIL IK | KIL1.5K | KIL 2.0K | KIL 2K | KIL 3K | KIL 4K | KIL 5K | KIL 6K | |
---|---|---|---|---|---|---|---|---|---|---|---|
Rated Power | 300W | 600W | 1000W | 1500W | 2000W | 2000W | 3000W | 4000W | 5000W | 6000W | |
Instantaneous Power | 900W | 1800W | 3000W | 4500W | 6000W | 6000W | 9000W | 12000W | 15000W | 18000W | |
Dimension | Dimension^ x WxH(mm) | 320x278 x133 | 550x295 x205 | ||||||||
Dimensions x WxH(mm) | 400x300 x205 | 620x380x280 | |||||||||
Weight | N.W.(KGSZPC) | 5.8 | 7.1 | 14 | 16 | 16 | 19.2 | 25.8 | 33.5 | 39 | 43.4 |
G.W.(KGSZPC) | 6.5 | 7.9 | 15.5 | 17.5 | 17.5 | 20.7 | 27.3 | 35.7 | 41.2 | 45.6 | |
AC Input | Voltage Range | 100/110/120/127/220/230VAC(+25%,-36%) | 100/110/120/127/220/230VAC(±25%) | ||||||||
Frequency Range | 50Hz/60Hz ± 2.5Hz | ||||||||||
Output | Battery Efficiency | 81% | 83% | 85% | |||||||
AC Efficiency | 93% | ||||||||||
Outpue Voltage | 100/110/120/127/220/230VAC (AC mode+10%, Battery Mode +5%) | ||||||||||
Outpue Frequency | 50Hz/60Hz ± 0.5Hz (AC Mode± 2.5Hz) | ||||||||||
Transfer time | 4ms/8ms(Optional) | ||||||||||
USB Outpue | DC 5V/1Ax1+5V/2Ax1 (Optional) | ||||||||||
Wave Form | Pure Sine Wave | ||||||||||
Input/Outpue | Input & Output terminals | ||||||||||
Conneclor | Battery | Terminals | |||||||||
Battery | Votage | 12VDC/24VDC | 24VDC | 48VDC | 24VDC/48VDC | 48VDC | |||||
Charging Current | 1-20A(Adjustable) | 3-60A(Adjustable) | |||||||||
LCD | Method | LCD+LED | |||||||||
Content | Input/Output Voltage, Battery Voltage, Battery Capacity, Load Capacity, Working mode,Frequency | ||||||||||
Prate ction | Battery Reversal | Optional | |||||||||
Output Short Circuit | AC mode: Jump fuse, Inverter mode: Shut down | ||||||||||
Overload | If Overload 105%, Inverter will alarm.If Overload 130%, Inverter will shut down in 10s.Once the inverter is off,It must be turned on manually | ||||||||||
High AC Voltage | Turn off AC, Turn to Inverter mode automatically | ||||||||||
Low DC Voltage | Inverter shut down automatically, Once the AC recover, Inverter turn on and charge automatically | ||||||||||
Over Temperature | inverter will alarm and turn off output but it will recover to normal state after cooling down | ||||||||||
Enviro nment | Humidity | 15-93% (No condensation ) | |||||||||
Temperature | -10°C~50°C | ||||||||||
Altitude | <3000m | ||||||||||