KEBOS POWER ,to continue a better life.
Parallel operation up to 4 units
Built in isolation transformer to provide pure power to connected devices.It also can be parallel operated with 4 units and expand the total capacity to 120KW.Users can easily expand their existing power rating by adding inverters.
Pure sine wave output
Self-consumption and Feed-in to the grid
Programmable supply priority for PV, Battery or Grid
True galvanic isolation transformer design
User-adjustable charging current
Programmable multiple operation modes: Grid-tie, off-grid and grid-tie with backup
Built-in timer for various mode of on/off operation
Multiple communication for USB, RS-232, Modbus and SNMP
Monitoring software for real-time status display and control
Parallel operation up to 4 units
MODEL | KH-I-TX-PA 30KW |
---|---|
MAXIMUM PV INPUT POWER | 45KW |
RATED OUTPUT POWER | 30KW |
MAXIMUM CHARGING POWER | 30KW |
GRID-TIE OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage | 720 VDC |
Maximum DC Voltage | 950 VDC |
Start-up Voltage / Initial Feeding Voltage | 500 VDC / 550 VDC |
MPP Voltage Range | 460 VDC ~ 900 VDC |
Full power MPP Voltage Range | 625 VDC ~ 900 VDC |
Number of MPP Trackers | 1 |
Maximum Input Current | 72 A |
GRID/UTILITY OUTPUT (AC) | |
Nominal Output Voltage | 230 VAC* (P-N) / 400 VAC (P-P) |
Output Voltage Range | 195.5 - 253 VAC per phase |
Output Frequency Range | 49 ~ 51 Hz or 59.3 ~ 60.5 Hz |
Nominal Output Current | 43.5 A per phase |
Power Factor | 1 |
EFFICIENCY | |
Maximum Conversion Efficiency (DC/AC) | 95% |
OFF-GRID OPERATION | |
AC INPUT | |
AC Start-up Voltage | 150 - 170 VAC per phase |
Auto Restart Voltage | 180 VAC per phase |
Acceptable Input Voltage Range | 170 - 280 VAC per phase |
Maximum AC Input Current | 43.5 A per phase |
PV INPUT (DC) | |
Maximum DC Power | 45KW |
Maximum DC Voltage | 950 VDC |
MPP Voltage Range | 460 VDC ~ 900 VDC |
Number of MPP Trackers | 1 |
Maximum Input Current | 72 A |
BATTERY MODE OUTPUT (AC) | |
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) |
Output Frequency | 50 Hz / 60 Hz (auto sensing) |
Output Waveform | Pure sine wave |
Efficiency (DC to AC) | >91% |
HYBRID OPERATION | |
PV INPUT (DC) | |
Maximum DC Power | 45KW |
Nominal DC Voltage | 720 VDC |
Maximum DC Voltage | 950 VDC |
Start-up Voltage / Initial Feeding Voltage | 500 VDC / 550 VDC |
MPP Voltage Range | 460 VDC ~ 900 VDC |
Number of MPP Trackers | 1 |
Maximum Input Current | 72 A |
GRID/UTILITY OUTPUT (AC) | |
Nominal Output Voltage | 230 VAC* (P-N) / 400 VAC (P-P) |
Output Voltage Range | 195.5 - 253 VAC per phase |
Output Frequency Range | 49 ~ 51 Hz or 59.3 ~ 60.5 Hz |
Nominal Output Current | 43.5 A per phase |
Power Factor | 1 |
AC INPUT | |
AC Start-up Voltage | 150 - 170 VAC per phase |
Auto Restart Voltage | 180 VAC per phase |
Acceptable Input Voltage Range | 170 - 280 VAC per phase |
Maximum AC Input Current | 43.5 A per phase |
BATTERY MODE OUTPUT (AC) | |
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) |
Output Frequency | 50 Hz / 60 Hz (auto sensing) |
Output Waveform | Pure sine wave |
Efficiency (DC to AC) | >91% |
BATTERY & CHARGER | |
Nominal Battery Voltage/Charging Voltage Range | 384 VDC / 384 VDC ~ 480 VDC |
Maximum Charging Current | 80 A |
GENERAL | |
PHYSICAL | |
Dimension, D X W X H (mm) | 430 x 715 x 1021 |
Net Weight (kgs) | 223 |
INTERACE | |
Communication Port | RS-232/USB |
Intelligent Slot | Optional SNMP, GPRS, WIFI, Modbus cards available |
ENVIRONMENT | |
Humidity | 0 ~ 90% RH (No condensing) |
Operating Temperature | -10 to 55°C |
Altitude | 0 ~ 1000 m** |
*These figures are based on VDE-4105 standard. All figures may vary depending on different AC voltage and country requirements. | |
** Power derating 1% every 100 m when altitude is over 1000m |