KEBOS POWER ,to continue a better life.
With Ingress protection to IP65,KH-I WP 10kW-15kW is suitable for use both in outdoor applications and indoor environments where atmospheric moisture and dust are present. Parallel operation max to 6 units for greater power and capacity, enables a powelrating of up to 90kW. This makes it possible to create energy solutions for homes, offices, and small commercial building applications.
IP65 waterproof and dustproof makes the inverter available for various working conditions
Built-in WiFi for mobile monitoring (App is available)
150% unbalanced load support
Dual outputs selected as either programmable output or generator input
User-adjustable charging current
Reserved communication port for BMS (RS485)
5 years warranty
Parallel operation up to 6 units
MODEL | KH-I WP 8KW | KH-I WP 10KW | KH-I WP 12KW | KH-I WP 15KW |
---|---|---|---|---|
MAXIMUM PV INPUT POWER | 10500W | 14500W | 16000W | 16000W |
RATED OUTPUT POWER | 8000 W | 10000 W | 12000 W | 15000 W |
MAXIMUM CHARGING POWER | 8000 W | 10000 W | 12000 W | 15000 W |
GRID-TIE OPERATION | ||||
PV INPUT (DC) | ||||
Nominal DC Voltage | 720 VDC | 720 VDC | 720 VDC | 720 VDC |
Maximum DC Voltage | 1000 VDC | 1000 VDC | 1000 VDC | 1000 VDC |
Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC | 320 VDC / 350 VDC | 320 VDC / 350 VDC | 320 VDC / 350 VDC |
MPP Voltage Range | 350 VDC ~ 950 VDC | 350 VDC ~ 950 VDC | 350 VDC ~ 950 VDC | 350 VDC ~ 950 VDC |
Number of MPP Trackers / Maxium Input Current | 2 / A: 13A, B: 13A | 2 / A: 27A, B: 13A | 2 / A: 27A, B: 27A | 2 / A: 27A, B: 27A |
Number of Strings Per MPP Tracker | A: 1, B: 1 | A: 2, B: 1 | A: 2, B: 2 | A: 2, B: 2 |
GRID/UTILITY OUTPUT (AC) | ||||
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range | 184 - 265 VAC per phase | 184 - 265 VAC per phase | 184 - 265 VAC per phase | 184 - 265 VAC per phase |
Output Frequency Range | 47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz | 47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz | 47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz | 47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz |
Nominal Output Current | 11.6 A per phase | 14.5 A per phase | 17.4 A per phase | 21.7 A per phase |
Power Factor range | 0.9 lag ~ 0.9 lead | 0.9 lag ~ 0.9 lead | 0.9 lag ~ 0.9 lead | 0.9 lag ~ 0.9 lead |
EFFICIENCY | ||||
Maximum Conversion Efficiency (DC/AC) | >96% | >96% | >96% | >96% |
European Efficiency@ V nominal | >95% | >95% | >95% | >95% |
OFF-GRID OPERATION | ||||
AC INPUT | ||||
AC Start-up Voltage | 120 - 140 VAC per phase | 120 - 140 VAC per phase | 120 - 140 VAC per phase | 120 - 140 VAC per phase |
Auto Restart Voltage | 180 VAC per phase | 180 VAC per phase | 180 VAC per phase | 180 VAC per phase |
Acceptable Input Voltage Range | 170 - 290 VAC per phase | 170 - 290 VAC per phase | 170 - 290 VAC per phase | 170 - 290 VAC per phase |
Maximum AC Input Current | 40 A | 40 A | 40 A | 40 A |
PV INPUT (DC) | ||||
Maximum DC Power | 10500W | 14500W | 16000W | 22500W |
Maximum DC Voltage | 1000 VDC | 1000 VDC | 1000 VDC | 1000 VDC |
MPP Voltage Range | 350 VDC ~ 950 VDC | 350 VDC ~ 950 VDC | 350 VDC ~ 950 VDC | 350 VDC ~ 950 VDC |
Number of MPP Trackers / Maxium Input Current | 2 / A: 13A, B: 13A | 2 / A: 27A, B: 13A | 2 / A: 27A, B: 27A | 2 / A: 27A, B: 27A |
Number of Strings Per MPP Tracker | A: 1, B: 1 | A: 2, B: 1 | A: 2, B: 2 | A: 2, B: 2 |
BATTERY MODE OUTPUT (AC) | ||||
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) |
Output Frequency | 50 Hz / 60 Hz (auto sensing) | 50 Hz / 60 Hz (auto sensing) | 50 Hz / 60 Hz (auto sensing) | 50 Hz / 60 Hz (auto sensing) |
Output Waveform | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave |
Efficiency (DC to AC) | 91% | 91% | 91% | 91% |
HYBRID OPERATION | ||||
PV INPUT (DC) | ||||
Maximum DC Power | 10500W | 14500W | 16000W | 22500W |
Nominal DC Voltage | 720 VDC | 720 VDC | 720 VDC | 720 VDC |
Maximum DC Voltage | 1000 VDC | 1000 VDC | 1000 VDC | 1000 VDC |
Start-up Voltage / Initial Feeding Voltage | 320 VDC / 350 VDC | 320 VDC / 350 VDC | 320 VDC / 350 VDC | 320 VDC / 350 VDC |
MPP Voltage Range | 350 VDC ~ 950 VDC | 350 VDC ~ 950 VDC | 350 VDC ~ 950 VDC | 350 VDC ~ 950 VDC |
Number of MPP Trackers / Maxium Input Current | 2 / A: 13A, B: 13A | 2 / A: 27A, B: 13A | 2 / A: 27A, B: 27A | 2 / A: 27A, B: 27A |
Number of Strings Per MPP Tracker | A: 1, B: 1 | A: 2, B: 1 | A: 2, B: 2 | A: 2, B: 2 |
GRID/UTILITY OUTPUT (AC) | ||||
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range | 184 - 265 VAC per phase | 184 - 265 VAC per phase | 184 - 265 VAC per phase | 184 - 265 VAC per phase |
Output Frequency Range | 47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz | 47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz | 47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz | 47.5 ~ 51.5 Hz or 59.3 ~ 60.5 Hz |
Nominal Output Current | 11.6 A per phase | 14.5 A per phase | 17.4 A per phase | 21.7 A per phase |
Power Factor range | 0.9 lag ~ 0.9 lead | 0.9 lag ~ 0.9 lead | 0.9 lag ~ 0.9 lead | 0.9 lag ~ 0.9 lead |
AC INPUT | ||||
AC Start-up Voltage | 120 - 140 VAC per phase | 120 - 140 VAC per phase | 120 - 140 VAC per phase | 120 - 140 VAC per phase |
Auto Restart Voltage | 180 VAC per phase | 180 VAC per phase | 180 VAC per phase | 180 VAC per phase |
Acceptable Input Voltage Range | 170 - 290 VAC per phase | 170 - 290 VAC per phase | 170 - 290 VAC per phase | 170 - 290 VAC per phase |
Maximum AC Input Current | 40 A | 40 A | 40 A | 40 A |
BATTERY MODE OUTPUT (AC) | ||||
Nominal Output Voltage | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) | 230 VAC (P-N) / 400 VAC (P-P) |
Output Frequency | 50 Hz / 60 Hz (auto sensing) | 50 Hz / 60 Hz (auto sensing) | 50 Hz / 60 Hz (auto sensing) | 50 Hz / 60 Hz (auto sensing) |
Output Waveform | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave |
Efficiency (DC to AC) | 91% | 91% | 91% | 91% |
BATTERY & CHARGER | ||||
Battery Voltage Range | 40 ~ 62 VDC | 40 ~ 62 VDC | 40 ~ 62 VDC | 40 ~ 62 VDC |
Maximum Charging Current | 190 A | 220 A | 250 A | 300 A |
GENERAL | ||||
PHYSICAL | ||||
Dimension, D X W X H (mm) | 247 x 500 x 650 | 247 x 500 x 650 | 255 x 660 x 750 | 255 x 660 x 750 |
Net Weight (kgs) | 42 | 42 | 75 | 78 |
IP protection | IP 65 | |||
INTERACE | ||||
Communication Port | RS-232, RS-485, USB, CAN and Wi-Fi | |||
Intelligent Slot | Optional for SNMP and Modbus cards | |||
ENVIRONMENT | ||||
Humidity | 0 ~ 100% RH (Non-condensing) | |||
Operating Temperature | -25 to 60°C, > 45°C power derating | |||
Altitude | 0 ~ 1000 m** | |||
*These figures are based on VDE-4105 standard. All figures may vary depending on different AC voltage and country requirements. | ||||
** Power derating 1% every 100 m when altitude is over 1000m | ||||
Product specifications are subject to change without further notice |